Cookies on this website

We use cookies to ensure that we give you the best experience on our website. If you click 'Accept all cookies' we'll assume that you are happy to receive all cookies and you won't see this message again. If you click 'Reject all non-essential cookies' only necessary cookies providing core functionality such as security, network management, and accessibility will be enabled. Click 'Find out more' for information on how to change your cookie settings.

PURPOSE: Q-space imaging (QSI) is a diffusion-weighted imaging (DWI) technique that enables investigation of tissue microstructure. However, for sufficient displacement resolution to measure the microstructure, QSI requires high q-values that are usually difficult to achieve with a clinical scanner. The recently introduced "low q-value method" fits the echo attenuation to only low q-values to extract the root mean square displacement. We investigated the clinical feasibility of the low q-value method for estimating the microstructure of the human corpus callosum using a 3.0-tesla clinical scanner within a clinically feasible scan time. METHODS: We performed a simulation to explore the acceptable range of maximum q-values for the low q-value method. We simulated echo attenuations caused by restricted diffusion in the intra-axonal space (IAS) and hindered diffusion in the extra-axonal space (EAS) assuming 100,000 cylinders with various diameters, and we estimated mean axon diameter, IAS volume fraction, and EAS diffusivity by fitting echo attenuations with different maximum q-values. Furthermore, we scanned the corpus callosum of 7 healthy volunteers and estimated the mean axon diameter and IAS volume fraction. RESULTS: Good agreement between estimated and defined values in the simulation study with maximum q-values of 700 and 800 cm(-1) suggested that the maximum q-value used in the in vivo experiment, 737 cm(-1), was reasonable. In the in vivo experiment, the mean axon diameter was larger in the body of the corpus callosum and smaller in the genu and splenium, and this anterior-to-posterior trend is consistent with previously reported histology, although our mean axon diameter seems larger in size. On the other hand, we found an opposite anterior-to-posterior trend, with high IAS volume fraction in the genu and splenium and a lower fraction in the body, which is similar to the fiber density reported in the histology study. CONCLUSION: The low q-value method may provide insights into tissue microstructure using a 3T clinical scanner within clinically feasible scan time.

Original publication

DOI

10.2463/mrms.2014-0141

Type

Journal article

Journal

Magn Reson Med Sci

Publication Date

2016

Volume

15

Pages

83 - 93

Keywords

Adult, Algorithms, Axons, Computer Simulation, Corpus Callosum, Diffusion Magnetic Resonance Imaging, Echo-Planar Imaging, Feasibility Studies, Humans, Image Enhancement, Image Processing, Computer-Assisted, Male, Models, Theoretical, Young Adult