We use cookies to ensure that we give you the best experience on our website. If you click 'Accept all cookies' we'll assume that you are happy to receive all cookies and you won't see this message again. If you click 'Reject all non-essential cookies' only necessary cookies providing core functionality such as security, network management, and accessibility will be enabled. Click 'Find out more' for information on how to change your cookie settings.

This work investigates the general problem of phase unwrapping for arbitrary N-dimensional phase maps. A cost function-based approach is outlined that leads to an integer programming problem. To solve this problem, a best-pair-first region merging approach is adopted as the optimization method. The algorithm was implemented and tested with 3D MRI medical data for venogram studies, as well as for fMRI applications in EPI unwarping and rapid, automated shimming.

Original publication

DOI

10.1002/mrm.10354

Type

Journal article

Journal

Magn Reson Med

Publication Date

01/2003

Volume

49

Pages

193 - 197

Keywords

Algorithms, Humans, Image Processing, Computer-Assisted, Imaging, Three-Dimensional, Magnetic Resonance Imaging, Veins