We use cookies to ensure that we give you the best experience on our website. If you click 'Accept all cookies' we'll assume that you are happy to receive all cookies and you won't see this message again. If you click 'Reject all non-essential cookies' only necessary cookies providing core functionality such as security, network management, and accessibility will be enabled. Click 'Find out more' for information on how to change your cookie settings.

Steady-state free precession (SSFP) is a highly-efficient MRI pulse sequence that has been a fairly recent arrival in the functional MRI realm. Several methods for using balanced SSFP to detect the BOLD signal have been proposed to date and will be discussed in this review. After a brief introduction to the general properties of SSFP, this review describes the quite different approaches of transition-band and pass-band SSFP in terms of functional contrast mechanism. It then discusses the potential advantages of these techniques, followed by their challenges and shortcomings. Finally, it gives an overview of some applications considered to date and the author's perspective on where these techniques are headed. In the spirit of this special issue, the author also includes some of the personal history underlying her own explorations in this area. © 2011 Elsevier Inc.

Original publication

DOI

10.1016/j.neuroimage.2011.10.040

Type

Journal article

Journal

NeuroImage

Publication Date

15/08/2012

Volume

62

Pages

713 - 719