Cookies on this website

We use cookies to ensure that we give you the best experience on our website. If you click 'Accept all cookies' we'll assume that you are happy to receive all cookies and you won't see this message again. If you click 'Reject all non-essential cookies' only necessary cookies providing core functionality such as security, network management, and accessibility will be enabled. Click 'Find out more' for information on how to change your cookie settings.

PURPOSE: To present a HOmologous Black-Bright-blood and flexible Interleaved imaging (HOBBI) sequence for dynamic contrast-enhanced magnetic resonance imaging (MRI) of the vessel wall. THEORY AND METHODS: A HOBBI sequence is proposed to acquire high-spatial-resolution black-blood and high-temporal-resolution bright-blood dynamic contrast-enhanced images in an interleaved fashion. Black-blood imaging allows for thin vessel wall evaluation, whereas bright-blood imaging obtains the arterial input function accurately. A simulation was performed to assess the accuracy of the pharmacokinetic parameters [transfer constant (K(trans) ) and fractional plasma volume (vp )] generated from HOBBI. In vivo evaluation was also used to validate HOBBI in an animal model of aortic atherosclerosis. RESULTS: In the simulation test, the estimated K(trans) and vp measured by HOBBI were more accurate than those from black-blood dynamic contrast-enhanced-MRI. In the animal model testing, K(trans) and vp also demonstrated good interscan reproducibility (K(trans) : ICC = 0.77, vp : ICC = 0.72, respectively). Additionally, K(trans) showed a significant increase from 1 month (0.026 ± 0.013 min(-1) ) to 2 months (0.069 ± 0.018 min(-1) ) in animal model plaque progression after balloon injury. CONCLUSION: The proposed HOBBI sequence was demonstrated to be feasible and accurate in estimating the pharmacokinetic parameters of the atherosclerotic vessel wall, and has potential to become an early screening tool for atherosclerosis disease.

More information Original publication

DOI

10.1002/mrm.25287

Type

Journal article

Publication Date

2015-05-01T00:00:00+00:00

Volume

73

Pages

1754 - 1763

Total pages

9

Keywords

atherosclerosis, dynamic contrast-enhanced-magnetic resonance imaging, sequence, Angioplasty, Balloon, Animals, Aorta, Abdominal, Atherosclerosis, Contrast Media, Gadolinium DTPA, Iliac Artery, Image Enhancement, Image Interpretation, Computer-Assisted, Image Processing, Computer-Assisted, Magnetic Resonance Imaging, Male, Rabbits